<xml><ArticleSet><Article><Journal><PublisherName>Radiance Research Academy</PublisherName><JournalTitle>International Journal of Current Research and Review</JournalTitle><PISSN>2231-2196</PISSN><EISSN>0975-5241</EISSN><Volume>18</Volume><Issue>17</Issue><IssueLanguage>English</IssueLanguage><SpecialIssue>N</SpecialIssue><PubDate><Year>2026</Year><Month>September</Month><Day>15</Day></PubDate></Journal><ArticleType>Healthcare</ArticleType><ArticleTitle>&#xD;
	Push Out Bond Strength Evaluation of Tenax Glass Fibre Post Cemented with Relyx U200, Escem and Relyx Luting 2 Cement: An In Vitro Study&#xD;
&#xD;
</ArticleTitle><ArticleLanguage>English</ArticleLanguage><FirstPage>01</FirstPage><LastPage>06</LastPage><AuthorList><Author>Bhoop Singh</Author><AuthorLanguage>English</AuthorLanguage><Author> Renu Bala Sroa</Author><AuthorLanguage>English</AuthorLanguage><Author> Baljeet Sidhu</Author><AuthorLanguage>English</AuthorLanguage><Author> Navjot Mann</Author><AuthorLanguage>English</AuthorLanguage><Author> Himanshi</Author><AuthorLanguage>English</AuthorLanguage><Author> Ravneet</Author><AuthorLanguage>English</AuthorLanguage><Author> Jasbir</Author><AuthorLanguage>English</AuthorLanguage></AuthorList><Abstract>&#xD;
	Background: Endodontically treated teeth with substantial loss of coronal tooth structure may require fiber post placement for&#xD;
	retention of the definitive restoration. The retention of fiber posts is influenced by the bonding between the post, luting cement,&#xD;
	and root canal dentin.&#xD;
	Aim: To comparatively evaluate the push-out bond strength of Tenax glass fiber posts cemented with RelyX U200, EsCem, and RelyX Luting 2.&#xD;
	Materials and Methods: Forty-five extracted human permanent central incisors were decoronated, biomechanically prepared&#xD;
	using ProTaper Gold files up to F3, and obturated with AH Plus sealer and F3 gutta-percha cones. Post spaces were prepared to a depth of 9 mm while maintaining a 4-mm apical seal. The specimens were randomly divided into three groups (n = 15): Group A (RelyX U200), Group B (EsCem), and Group C (RelyX Luting 2). Tenax glass fiber posts were cemented according to the respective group protocols. The specimens were sectioned to obtain coronal and middle root segments of 4 &#xB1; 0.1 mm thickness and subjected to push-out bond strength testing using a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed using one-way analysis of variance and Tukey&#x2019;s post-hoc test.&#xD;
	Results: The mean push-out bond strength in the coronal and middle thirds was 17.54 and 15.35 MPa for Group A, 15.95 and&#xD;
	15.05 MPa for Group B, and 14.25 and 14.64 MPa for Group C, respectively. A statistically significant difference was observed&#xD;
	among the groups in the coronal third (p = 0.003).&#xD;
	Conclusion: Within the limitations of the present in vitro study, RelyX U200 demonstrated the highest mean push-out bond&#xD;
	strength among the tested luting materials, with a statistically significant advantage over RelyX Luting 2 in the coronal third.&#xD;
&#xD;
</Abstract><AbstractLanguage>English</AbstractLanguage><Keywords>Fiber post; Tenax glass fiber post; Self-adhesive resin cement; Push-out bond strength; RelyX U200; EsCem.</Keywords><URLs><Abstract>http://ijcrr.com/abstract.php?article_id=4922</Abstract><Fulltext>http://ijcrr.com/article_html.php?did=4922</Fulltext></URLs></Article></ArticleSet></xml>